Tosoh AIA-PACK FSH Calibration Verification/Linearity Set – AIA-360 / 600 II / 900 (Cat. No. 0020665)
Tosoh AIA-PACK FSH Calibration Verification/Linearity Set – AIA-360 / 600 II / 900 (Cat. No. 0020665)
Couldn't load pickup availability
What is it:
The Tosoh AIA-PACK FSH Calibration Verification/Linearity Set is a genuine Tosoh material used to verify the reportable range of the Follicle-Stimulating Hormone (FSH) assay across Tosoh AIA analyzers. It's distinct from routine calibration — this set confirms the assay reports accurately across its full measuring span.
Part numbers:
- Cat. No.: 0020665
- Also searchable as (previous Tosoh part numbers): 020665, 20665
What it's used for:
Calibration verification/linearity testing is typically performed on a scheduled basis (e.g., semi-annually) or whenever required by CLIA/accreditation standards, confirming that results remain accurate across the low, mid, and high end of the FSH assay's reportable range — not just at a single calibration point.
What's included:
SDS (Sample Diluting Solution), 2 x 4 mL, and CVM (Calibration Verification Material), 2 x 2 mL. Manufactured by Tosoh Corporation.
Compatible analyzers:
- Tosoh AIA-360
- Tosoh AIA-600 II
- Tosoh AIA-900
Storage & shipping:
Contact us before ordering if you have a deadline — we'll confirm availability upfront so you know exactly when it'll arrive.
Why labs order from Transperify:
- ✅ Genuine Tosoh AIA-PACK verification set, correct Cat. No. guaranteed
- ✅ Transparent pricing — no login required to see cost
- ✅ Competitively priced (typically below major distributor list pricing)
- ✅ Fast, reliable U.S. fulfillment
- ✅ Easy reorder for scheduled linearity/CLIA verification
👉 Add to cart above, or browse our full [Tosoh AIA catalog] for more reagents, calibrators, and consumables.
Questions about compatibility or your reorder? 📩 customersupport@transperify.com
FAQs:
What is the Tosoh AIA-PACK FSH Calibration Verification/Linearity Set used for?
It verifies that the FSH assay reports accurately across its full measuring range, distinct from routine calibration — often used to meet CLIA or accreditation requirements.
What's the difference between this and a calibrator set?
A calibrator set establishes the assay's standard curve. This linearity set instead confirms the assay's reportable range is accurate at multiple points across its span.
What's included in the set?
SDS, 2 x 4 mL, and CVM, 2 x 2 mL.
Which analyzers is Cat. No. 0020665 compatible with?
The AIA-360, AIA-600 II, and AIA-900.