What is it:
The Horiba ABX Pentra LDL Calibrator (P/N 1220001678, REF A11A01678) is a genuine HORIBA calibrator for the ABX Pentra 400 / Pentra C400 clinical chemistry analyzer, used to calibrate the analyzer's LDL (low-density lipoprotein) cholesterol assay. Supplied as 2 × 1 mL. For professional in vitro diagnostic use.
Part numbers:
- Catalog P/N: 1220001678
- Box REF: A11A01678
What it's used for:
The LDL Calibrator establishes the known reference point the Pentra 400 uses to produce accurate LDL cholesterol results. By assigning the analyzer's LDL assay to a material of known concentration, the calibrator ensures patient LDL values read true — essential for lipid-panel testing used in cardiovascular risk assessment. Calibrators are run on a defined schedule (and after reagent lot changes or QC shifts), so this is a recurring item for labs running LDL testing.
What's included:
- 1 × Horiba ABX Pentra LDL Calibrator kit (2 × 1 mL)
- Catalog P/N: 1220001678 · Box REF: A11A01678
- For professional in vitro diagnostic (IVD) use only
- Manufactured by HORIBA ABX SAS
Compatible analyzer:
- ABX Pentra 400 (Pentra C400) Clinical Chemistry Analyzer
This is the LDL cholesterol calibrator for the Pentra 400 / C400. Calibrators are assay-specific — confirm this matches the LDL assay your lab runs. Not for use with non-HORIBA instruments.
Storage & shipping note:
Store refrigerated (2–8°C). Ships cold-chain with priority handling to protect calibrator integrity. Carries a GHS "Warning" classification — follow the Safety Data Sheet for handling and disposal. Non-returnable once shipped.
Why labs order from Transperify:
- ✅ Genuine HORIBA ABX product, correct REF guaranteed
- ✅ Transparent pricing — no login required to see cost
- ✅ Competitively priced (typically below major distributor list pricing)
- ✅ Fast, reliable U.S. fulfillment
- ✅ Easy reorder for recurring calibrators and QC materials
👉 Add to cart above, or browse our full [Horiba ABX Pentra catalog] for more calibrators, controls, and reagents.
Questions about compatibility or your reorder? 📩 customersupport@transperify.com
FAQs:
What is the Horiba ABX Pentra LDL Calibrator used for?
It calibrates the LDL (low-density lipoprotein) cholesterol assay on the Pentra 400 / C400, establishing a known reference point so patient LDL results read accurately. It's used as part of routine lipid-panel testing.
Which analyzer is P/N 1220001678 compatible with?
The HORIBA ABX Pentra 400 / Pentra C400 clinical chemistry analyzer.
How much is in the kit?
The kit contains 2 × 1 mL.
How often should I calibrate LDL?
Follow your reagent insert and lab QC policy — typically on a set schedule and after reagent lot changes, major maintenance, or QC shifts. Your lab director's protocol governs frequency.
Does it need refrigeration?
Yes. Store refrigerated at 2–8°C, and the product ships with cold-chain handling.
What's the difference between a calibrator and a control?
A calibrator sets the analyzer's reference point so results are accurate; a control then verifies that calibration is holding during routine QC. They're different products used together — order the one your procedure calls for.
What's the difference between the box REF and the catalog number?
The box shows REF A11A01678; distributors order it as P/N 1220001678. They're the same product — we list both so you find this page from either number.