Horiba ABX Pentra LDH IFCC CP Reagent – ~125 Tests – Pentra 400 / C400 (P/N 1220001871)

Horiba ABX Pentra LDH IFCC CP Reagent – ~125 Tests – Pentra 400 / C400 (P/N 1220001871)

Regular price $42.95 USD
Regular price $56.12 USD Sale price $42.95 USD
Sale Sold out

What is it:

The Horiba ABX Pentra LDH IFCC CP (P/N 1220001871, REF A11A01871) is a genuine HORIBA reagent for measuring lactate dehydrogenase (LDH) on the ABX Pentra 400 / Pentra C400 clinical chemistry analyzer. It uses the IFCC-standardized kinetic UV method and is supplied as a ready-to-use bi-reagent cassette (Reagent 1: 26 mL · Reagent 2: 6.5 mL), good for approximately 125 tests. For professional in vitro diagnostic use.

Part numbers:

  • Catalog P/N: 1220001871
  • Box REF: A11A01871

What it's used for:

LDH CP measures lactate dehydrogenase activity in serum and plasma — an enzyme marker used in the diagnosis and monitoring of liver disease, cardiac conditions, certain cancers, hemolysis, and tissue damage. The assay uses the IFCC-standardized kinetic UV method: LDH catalyzes the conversion of lactate to pyruvate with reduction of NAD⁺ to NADH, and the analyzer tracks the rate of NADH formation at 340 nm, proportional to LDH activity. Following the IFCC reference method means results are standardized and comparable across laboratories. As a routine enzyme test, this is a regularly reordered reagent, used together with the appropriate calibrator and controls.

What's included:

  • 1 × ABX Pentra LDH IFCC CP bi-reagent cassette
  • Reagent 1: 26 mL · Reagent 2: 6.5 mL
  • Approximately 125 tests per cassette
  • Manufactured by HORIBA ABX SAS

Compatible analyzer:

  • ABX Pentra 400 (Pentra C400) Clinical Chemistry Analyzer

This is the LDH measurement reagent for the Pentra 400 / C400, standardized to the IFCC method. It's distinct from the calibrator and controls used to standardize and monitor the assay. Not for use with non-HORIBA instruments.

Storage & shipping note:

Store refrigerated (2–8°C). Ships cold-chain with priority handling. Non-returnable once shipped.

Why labs order from Transperify:

  • ✅ Genuine HORIBA ABX product, correct REF guaranteed
  • ✅ Transparent pricing — no login required to see cost
  • ✅ Competitively priced (typically below major distributor list pricing)
  • ✅ Fast, reliable U.S. fulfillment
  • ✅ Easy reorder for recurring clinical chemistry reagents

👉 Add to cart above, or browse our full [Horiba ABX Pentra catalog] for more reagents, calibrators, and controls.

Questions about compatibility or your reorder? 📩 customersupport@transperify.com

FAQs:

What is the Horiba ABX Pentra LDH IFCC CP used for?

It's the reagent that measures lactate dehydrogenase (LDH) on the Pentra 400 / C400 using the IFCC-standardized kinetic UV method. LDH is used in the diagnosis and monitoring of liver and cardiac disease, hemolysis, tissue damage, and some cancers.

What does "IFCC" mean?

IFCC refers to the International Federation of Clinical Chemistry reference method for LDH. Using the IFCC-standardized method means results are harmonized and comparable across labs and instruments that follow the same standard.

Which analyzer is P/N 1220001871 compatible with?

The HORIBA ABX Pentra 400 / Pentra C400 clinical chemistry analyzer.

How many tests does one cassette provide?

Approximately 125 tests. Actual yield depends on your calibration and QC frequency.

What method does it use?

The IFCC kinetic UV method — LDH converts lactate to pyruvate while reducing NAD⁺ to NADH, and the analyzer measures the rate of NADH formation at 340 nm, proportional to LDH activity.

Does it need refrigeration?

Yes. Store refrigerated at 2–8°C, and the product ships with cold-chain handling.

What's the difference between the box REF and the catalog number?

The box shows REF A11A01871; distributors order it as P/N 1220001871. They're the same product — we list both so you find this page from either number.