Horiba ABX Pentra CRP Calibrator – Pentra 400 / C400 (P/N 1220001616)
Horiba ABX Pentra CRP Calibrator – Pentra 400 / C400 (P/N 1220001616)
Couldn't load pickup availability
What is it:
The Horiba ABX Pentra CRP Calibrator (P/N 1220001616, REF A11A01616) is a genuine HORIBA liquid calibrator for the ABX Pentra 400 / Pentra C400 clinical chemistry analyzer, used to calibrate the C-reactive protein (CRP) assay. For professional in vitro diagnostic use.
Part numbers:
- Catalog P/N: 1220001616
- Box REF: A11A01616
What it's used for:
The CRP Calibrator establishes the known reference point the Pentra 400 uses to produce accurate C-reactive protein results. CRP is a key marker of inflammation and infection, widely used to detect and monitor inflammatory conditions and to assess infection severity. By assigning the analyzer's CRP assay to a calibrator of known concentration, this product ensures patient CRP values read true. Calibrators are run on a defined schedule (and after reagent lot changes or QC shifts), so this is a recurring item for labs running CRP testing.
What's included:
- Horiba ABX Pentra CRP Calibrator
Compatible analyzer:
- ABX Pentra 400 (Pentra C400) Clinical Chemistry Analyzer
This is the CRP calibrator for the Pentra 400 / C400 — it calibrates the CRP assay and is distinct from the CRP control (which verifies QC) and the CRP reagent (which runs the test). Calibrators are assay-specific; confirm this matches the CRP assay your lab runs. Not for use with non-HORIBA instruments.
Storage & shipping note:
Store refrigerated (2–10°C). Ships cold-chain with priority handling to protect calibrator integrity. Contains material of human origin — handle as potentially biohazardous and follow standard precautions and the package insert. Non-returnable once shipped.
Why labs order from Transperify:
- ✅ Genuine HORIBA ABX product, correct REF guaranteed
- ✅ Transparent pricing — no login required to see cost
- ✅ Competitively priced (typically below major distributor list pricing)
- ✅ Fast, reliable U.S. fulfillment
- ✅ Easy reorder for recurring calibrators and QC materials
👉 Add to cart above, or browse our full [Horiba ABX Pentra catalog] for more calibrators, controls, and reagents.
Questions about compatibility or your reorder? 📩 customersupport@transperify.com
FAQs:
What is the Horiba ABX Pentra CRP Calibrator used for?
It calibrates the C-reactive protein (CRP) assay on the Pentra 400 / C400, establishing a known reference point so patient CRP results read accurately. CRP is a widely used marker of inflammation and infection.
Which analyzer is P/N 1220001616 compatible with?
The HORIBA ABX Pentra 400 / Pentra C400 clinical chemistry analyzer.
How is the CRP Calibrator different from the CRP Control?
A calibrator sets the analyzer's reference point so CRP results are accurate; a control then verifies that calibration is holding during routine QC. They're different products used together — order the one your procedure calls for.
How much is in the kit?
Refer to the box/insert for the exact vial count and volume. If you'd like, send us a clear photo of the box label and we'll confirm before you order.
How often should I calibrate CRP?
Follow your reagent insert and lab QC policy — typically on a set schedule and after reagent lot changes, major maintenance, or QC shifts. Your lab director's protocol governs frequency.
Does it need refrigeration?
Yes. Store refrigerated at 2–10°C, and the product ships with cold-chain handling.
What's the difference between the box REF and the catalog number?
The box shows REF A11A01616; distributors order it as P/N 1220001616. They're the same product — we list both so you find this page from either number.