Transperify
Horiba ABX Pentra CRP CP Reagent – ~200 Tests – Pentra 400 / C400 (P/N 1220001611)
Horiba ABX Pentra CRP CP Reagent – ~200 Tests – Pentra 400 / C400 (P/N 1220001611)
Couldn't load pickup availability
What is it:
The Horiba ABX Pentra CRP CP (P/N 1220001611, REF A11A01611) is a genuine HORIBA reagent for measuring C-reactive protein (CRP) on the ABX Pentra 400 / Pentra C400 clinical chemistry analyzer. It uses a latex-enhanced immunoturbidimetric method and is supplied as a ready-to-use bi-reagent cassette (Reagent 1: 25 mL · Reagent 2: 23.5 mL), good for approximately 200 tests. For professional in vitro diagnostic use.
Part numbers:
- Catalog P/N: 1220001611
- Box REF: A11A01611
What it's used for:
CRP CP measures C-reactive protein, a key marker of inflammation and infection used to detect and monitor inflammatory conditions and assess infection severity. The assay works by latex-enhanced immunoturbidimetry: CRP in the sample binds anti-CRP antibodies coated on latex particles, causing agglutination that the analyzer measures as a change in turbidity, proportional to the CRP concentration. Because CRP is a high-volume, frequently ordered test, this is a routinely reordered reagent. It's used together with the CRP Calibrator (P/N 1220001616) and appropriate CRP/protein controls.
What's included:
- 1 × ABX Pentra CRP CP bi-reagent cassette
- Reagent 1: 25 mL · Reagent 2: 23.5 mL
- Approximately 200 tests per cassette
- Manufactured by HORIBA ABX SAS
Compatible analyzer:
- ABX Pentra 400 (Pentra C400) Clinical Chemistry Analyzer
This is the CRP measurement reagent. It's distinct from the CRP Calibrator (P/N 1220001616, which calibrates the assay) and from CRP/protein controls (which verify QC). Note: HORIBA also offers a high-sensitivity CRP (CRP HS) line with its own reagent and calibrator — confirm whether your protocol uses standard CRP or CRP HS before ordering. Not for use with non-HORIBA instruments.
Storage & shipping note:
Store refrigerated (2–10°C). Ships cold-chain with priority handling. Non-returnable once shipped.
Why labs order from Transperify:
- ✅ Genuine HORIBA ABX product, correct REF guaranteed
- ✅ Transparent pricing — no login required to see cost
- ✅ Competitively priced (typically below major distributor list pricing)
- ✅ Fast, reliable U.S. fulfillment
- ✅ Easy reorder for recurring clinical chemistry reagents
👉 Add to cart above, or browse our full [Horiba ABX Pentra catalog] for more reagents, calibrators, and controls.
Questions about compatibility or your reorder? 📩 customersupport@transperify.com
FAQs:
What is the Horiba ABX Pentra CRP CP used for?
It's the reagent that measures C-reactive protein (CRP) on the Pentra 400 / C400 by latex-enhanced immunoturbidimetry. CRP is a widely used marker of inflammation and infection.
Which analyzer is P/N 1220001611 compatible with?
The HORIBA ABX Pentra 400 / Pentra C400 clinical chemistry analyzer.
How many tests does one cassette provide?
Approximately 200 tests. Actual yield depends on your calibration and QC frequency.
What method does it use?
Latex-enhanced immunoturbidimetric assay (TIA) — CRP binds antibody-coated latex particles, and the resulting turbidity change is measured to determine concentration.
Is this standard CRP or high-sensitivity CRP (CRP HS)?
This is the standard CRP CP reagent. HORIBA offers a separate high-sensitivity CRP (CRP HS) line with its own reagent and calibrator. If your lab runs hsCRP, confirm you're ordering the correct line before purchasing — send us your method and we'll help.
Does it need refrigeration?
Yes. Store refrigerated at 2–10°C, and the product ships with cold-chain handling.
What's the difference between the box REF and the catalog number?
The box shows REF A11A01611; distributors order it as P/N 1220001611. They're the same product — we list both so you find this page from either number.
Share
