Transperify
Horiba ABX Pentra ALP CP Reagent – ~125 Tests – Pentra 400 / C400 (P/N 1220001626)
Horiba ABX Pentra ALP CP Reagent – ~125 Tests – Pentra 400 / C400 (P/N 1220001626)
Couldn't load pickup availability
What is it:
The Horiba ABX Pentra ALP CP (P/N 1220001626, REF A11A01626) is a genuine HORIBA reagent for measuring alkaline phosphatase (ALP) on the ABX Pentra 400 / Pentra C400 clinical chemistry analyzer. It uses a kinetic photometric method with p-nitrophenylphosphate and is supplied as a ready-to-use bi-reagent cassette (Reagent 1: 26 mL · Reagent 2: 6.5 mL), good for approximately 125 tests. For professional in vitro diagnostic use.
Part numbers:
- Catalog P/N: 1220001626
- Box REF: A11A01626
What it's used for:
ALP CP measures alkaline phosphatase (ALP) activity in serum and plasma — an enzyme marker used in the diagnosis and monitoring of liver, bone, parathyroid, and intestinal disorders. The assay uses a kinetic photometric method: ALP hydrolyzes the colorless substrate p-nitrophenylphosphate (pNPP) to p-nitrophenol, a yellow product, and the analyzer measures the rate of color formation, proportional to the ALP activity. As a routine liver- and bone-panel enzyme test, this is a regularly reordered reagent, used together with the appropriate calibrator and controls.
What's included:
- 1 × ABX Pentra ALP CP bi-reagent cassette
- Reagent 1: 26 mL · Reagent 2: 6.5 mL
- Approximately 125 tests per cassette
- Manufactured by HORIBA ABX SAS
Compatible analyzer:
- ABX Pentra 400 (Pentra C400) Clinical Chemistry Analyzer
This is the alkaline phosphatase (ALP) measurement reagent for the Pentra 400 / C400. It's distinct from the calibrator and controls used to standardize and monitor the assay. Not for use with non-HORIBA instruments.
Storage & shipping note:
Store refrigerated (2–8°C). Ships cold-chain with priority handling. Non-returnable once shipped.
Why labs order from Transperify:
- ✅ Genuine HORIBA ABX product, correct REF guaranteed
- ✅ Transparent pricing — no login required to see cost
- ✅ Competitively priced (typically below major distributor list pricing)
- ✅ Fast, reliable U.S. fulfillment
- ✅ Easy reorder for recurring clinical chemistry reagents
👉 Add to cart above, or browse our full [Horiba ABX Pentra catalog] for more reagents, calibrators, and controls.
Questions about compatibility or your reorder? 📩 customersupport@transperify.com
FAQs:
What is the Horiba ABX Pentra ALP CP used for?
It's the reagent that measures alkaline phosphatase (ALP) on the Pentra 400 / C400 using a kinetic photometric method with p-nitrophenylphosphate. ALP is used in the diagnosis and monitoring of liver, bone, parathyroid, and intestinal disorders.
Which analyzer is P/N 1220001626 compatible with?
The HORIBA ABX Pentra 400 / Pentra C400 clinical chemistry analyzer.
How many tests does one cassette provide?
Approximately 125 tests. Actual yield depends on your calibration and QC frequency.
What method does it use?
A kinetic photometric method — ALP hydrolyzes p-nitrophenylphosphate (pNPP) to the yellow product p-nitrophenol, and the analyzer measures the rate of color formation in proportion to the ALP activity.
Does it need refrigeration?
Yes. Store refrigerated at 2–8°C, and the product ships with cold-chain handling.
What's the difference between the box REF and the catalog number?
The box shows REF A11A01626; distributors order it as P/N 1220001626. They're the same product — we list both so you find this page from either number.